Loading data, please wait...
Voice of Customer & Requirements
Total Requirements
5
Released
4
In Progress
1
Needs Review
0
Current (Rev B) content:
Motor shall deliver a minimum peak torque of 350 Nm at the output shaft under nominal 400V DC bus voltage.
Target: 350 Nm · Tolerance: ±5 Nm
Verification: Dynamometer test at rated voltage
Revision History
Current (Rev A) content:
Motor shall maintain a continuous output power of 150 kW at operating temperature without exceeding thermal limits.
Target: 150 kW · Tolerance: −0/+10 kW
Verification: Thermal steady-state dynamometer test
Motor housing and all connectors shall achieve IP67 rating per IEC 60529 throughout the service life of the vehicle.
Target: IP67 · Tolerance: No deviation permitted
Verification: Ingress protection test per IEC 60529 §14.2.8
Motor shall operate across a DC bus voltage range of 250 V to 450 V without performance degradation outside the derating curve.
Target: 250–450 V DC
Verification: Bench test across voltage sweep profile
Motor shall operate reliably across an ambient temperature range of −40°C to +85°C and a coolant inlet temperature of up to 65°C.
Target: −40°C to +85°C
Verification: Thermal chamber with simultaneous load cycling